Grid Overview
| Grid specification: | |
|---|---|
| Grid number: | 96 |
| Number of APDs: | 20 |
| Grid information: | |
| Arrival for irradiation: | 03. Aug 2017 |
| Date of irradiation: | 09. Aug 2017 |
| Irradiation temperature: | 20 °C |
| Irradiation voltage: | individual voltage |
| Irradiation dose: | 45 Gy |
| Irradiation position: | 4 |
| Shipped for annealing/analysis: | 17. Aug 2017 |
| Annealing date: | none |
| Annealing temperature: | none |
| Annealing duration: | none |
| Return for assembly: | none |
| Operations: | Enter irradiation data • Enter annealing data • Enter shipment data |
| Grid overview: | |
| Slot 0: | 0808007812 (HV connected) |
| Slot 1: | 0808007823 (HV connected) |
| Slot 2: | 0808007813 (HV connected) |
| Slot 3: | 0808007824 (HV connected) |
| Slot 4: | 0808007814 (HV connected) |
| Slot 5: | 0808007825 (HV connected) |
| Slot 6: | 0808007815 (HV connected) |
| Slot 7: | 0808007826 (HV connected) |
| Slot 8: | 0808007816 (HV connected) |
| Slot 9: | 0808007827 (HV connected) |
| Slot 10: | 0808007817 (HV connected) |
| Slot 11: | 0808007828 (HV connected) |
| Slot 12: | 0808007818 (HV connected) |
| Slot 13: | 0808007829 (HV connected) |
| Slot 14: | 0808007819 (HV connected) |
| Slot 15: | 0808007830 (HV connected) |
| Slot 16: | 0808007820 (HV connected) |
| Slot 17: | 0808007831 (HV connected) |
| Slot 18: | 0808007822 (HV connected) |
| Slot 19: | 0808007832 (HV connected) |