RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show unit UA1691


This is all the information about the unit UA1691. If it is wrong, edit the data.

Unit specification:  
Database number: 98
Detector: Hamamatsu Vacuum Photo Tetrode UA1691
Submodule: 11072014-2 - 3-X1Y5-Dprevious (C) • in submodule • next (E)
Crystal: 3109
Barcode: 1309001002
   
Measured data:  
Yield (cosmics) for VPTT: 3.1614 ± 0.026 at 999 V and -24 °C
Length: 75 mm
   
Notes:


Detector

Detector specification:  
Serial number: UA1691
Type: Hamamatsu Vacuum Photo Tetrode
Preamp: 898
   
Measured data:  
DC gain: 52.22
Anode dark current: 0.023905 nA
Yield: -1
Notes:


Glueing photos

Creation time Notes
05. Jul 2017 11:22:07 CEST PR-1200 glueing + 1kg pressure


Upload new photo...

Teststand results

Creation time Detector Notes
12. Nov 2018 14:35:39 CET VPTT High Gain
12. Nov 2018 14:35:39 CET VPTT Low Gain

 
 

Version history

Time Author Change comment
30. Mar 2022 18:54:42 CEST seifen Updated cosmis calibration results via API.
25. Oct 2018 15:15:13 CEST fgrimm assigned to submodule
14. Sep 2018 14:52:50 CEST Tobias Unassigned from submodule because assignment was done according to old matching.
11. Jun 2017 18:08:22 CEST cschnier Assigned to alveole by script
11. Jun 2017 18:08:06 CEST cschnier Auto-created by unit assembly script