RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show unit UA0225


This is all the information about the unit UA0225. If it is wrong, edit the data.

Unit specification:  
Database number: 817
Detector: Hamamatsu Vacuum Photo Tetrode UA0225
Submodule: 22072014-2 - 1-X2Y3-Cprevious (B) • in submodule • next (D)
Crystal: 3998
Barcode: 1309003884
   
Measured data:  
Yield (cosmics) for VPTT: 2.4749 ± 0.0289 at 969.2 V and -24 °C
Length: 0 mm
   
Notes:


Detector

Detector specification:  
Serial number: UA0225
Type: Hamamatsu Vacuum Photo Tetrode
Preamp: 283
   
Measured data:  
DC gain: 51.14
Anode dark current: -1 nA
Yield: -1
Notes:


Glueing photos

Creation time Notes
05. Nov 2018 14:29:03 CET
05. Nov 2018 14:29:09 CET
05. Nov 2018 14:29:14 CET


Upload new photo...

Teststand results

Creation time Detector Notes
12. Nov 2018 14:37:28 CET VPTT High Gain
12. Nov 2018 14:37:28 CET VPTT Low Gain

 
 

Version history

Time Author Change comment
30. Mar 2022 18:54:13 CEST seifen Updated cosmis calibration results via API.
05. Nov 2018 14:17:23 CET fgrimm Assigned to submodule by script
05. Nov 2018 14:17:15 CET fgrimm Auto-created by unit assembly script