RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show unit UA1369


This is all the information about the unit UA1369. If it is wrong, edit the data.

Unit specification:  
Database number: 69
Detector: Hamamatsu Vacuum Photo Tetrode UA1369
Submodule: unassigned
Crystal: 1308
Barcode: 1309000722
   
Measured data:  
Yield (cosmics) for VPTT: not yet measured/stored
Length: 75 mm
   
Notes: NB 2/171 brown cupboard


Detector

Detector specification:  
Serial number: UA1369
Type: Hamamatsu Vacuum Photo Tetrode
Preamp: 891
   
Measured data:  
DC gain: 51.68
Anode dark current: 0.032045 nA
Yield: -1
Notes:


Glueing photos

Creation time Notes
05. Jul 2017 15:17:25 CEST PR-1200 glueing + 1kg pressure


Upload new photo...

Teststand results

Creation time Detector Notes
No teststand results available!

 
 

Version history

Time Author Change comment
23. Nov 2023 08:53:20 CET tholtmann Note added
13. Sep 2018 18:55:40 CEST tobias Resetted submodule assignment because it was from test submodule that has been disassembled.
07. Jun 2017 11:07:55 CEST cschnier Assigned to alveole by script
07. Jun 2017 11:07:30 CEST cschnier Auto-created by unit assembly script