Show unit UA1162
This is all the information about the unit UA1162. If it is wrong, edit the data.
| Unit specification: | |
|---|---|
| Database number: | 675 |
| Detector: | Hamamatsu Vacuum Photo Tetrode UA1162 |
| Submodule: | 12032014-02 - 4-X3Y3-Fprevious (E) • in submodule • next |
| Crystal: | 4284 |
| Barcode: | 1309007615 |
| Measured data: | |
| Yield (cosmics) for VPTT: | 2.8092 ± 0.0299 at 931.5 V and -24 °C |
| Length: | 0 mm |
| Notes: |
Detector
| Detector specification: | |
|---|---|
| Serial number: | UA1162 |
| Type: | Hamamatsu Vacuum Photo Tetrode |
| Preamp: | 139 |
| Measured data: | |
| DC gain: | 49.94 |
| Anode dark current: | 0.030963 nA |
| Yield: | 0 |
| Notes: |
Glueing photos
| Creation time | Notes |
|---|---|
| 08. Oct 2018 14:56:47 CEST | |
| 08. Oct 2018 14:56:51 CEST |
Teststand results
| Creation time | Detector | Notes |
|---|---|---|
| 04. Nov 2018 00:48:22 CET | VPTT | High Gain |
| 04. Nov 2018 00:48:22 CET | VPTT | Low Gain |
Version history
| Time | Author | Change comment |
|---|---|---|
| 30. Mar 2022 18:55:09 CEST | seifen | Updated cosmis calibration results via API. |
| 08. Oct 2018 14:50:56 CEST | fgrimm | Assigned to submodule by script |
| 08. Oct 2018 14:50:48 CEST | fgrimm | Auto-created by unit assembly script |