RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show unit UA0463


This is all the information about the unit UA0463. If it is wrong, edit the data.

Unit specification:  
Database number: 553
Detector: Hamamatsu Vacuum Photo Tetrode UA0463
Submodule: 28-2-2014-2 - 1-X1Y3-7previous (6) • in submodule • next (8)
Crystal: 3267
Barcode: 1309005895
   
Measured data:  
Yield (cosmics) for VPTT: 2.5785 ± 0.0254 at 954.2 V and -24 °C
Length: 0 mm
   
Notes:


Detector

Detector specification:  
Serial number: UA0463
Type: Hamamatsu Vacuum Photo Tetrode
Preamp: 332
   
Measured data:  
DC gain: 49.77
Anode dark current: 0.041814 nA
Yield: 0
Notes:


Glueing photos

Creation time Notes
16. Nov 2021 13:47:20 CET Original file name: capture000007.jpg


Upload new photo...

Teststand results

Creation time Detector Notes
04. Nov 2018 00:42:34 CET VPTT High Gain
04. Nov 2018 00:42:34 CET VPTT Low Gain

 
 

Version history

Time Author Change comment
30. Mar 2022 18:54:07 CEST seifen Updated cosmis calibration results via API.
20. Sep 2018 12:13:47 CEST fgrimm Assigned to submodule by script
20. Sep 2018 12:13:39 CEST fgrimm Auto-created by unit assembly script