RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show unit UA0173


This is all the information about the unit UA0173. If it is wrong, edit the data.

Unit specification:  
Database number: 359
Detector: Hamamatsu Vacuum Photo Tetrode UA0173
Submodule: 23092014-1 - 4-X1Y5-Bprevious (A) • in submodule • next (C)
Crystal: 1259
Barcode: 1309003754
   
Measured data:  
Yield (cosmics) for VPTT: 2.2843 ± 0.0193 at 950 V and -24 °C
Length: 0 mm
   
Notes:


Detector

Detector specification:  
Serial number: UA0173
Type: Hamamatsu Vacuum Photo Tetrode
Preamp: 113
   
Measured data:  
DC gain: 45.61
Anode dark current: 0.000502 nA
Yield: 0
Notes:


Glueing photos

Creation time Notes
13. Aug 2018 11:47:28 CEST PR-1200 glueing + 1kg pressure


Upload new photo...

Teststand results

Creation time Detector Notes
13. Sep 2018 18:03:25 CEST VPTT High Gain
13. Sep 2018 18:03:25 CEST VPTT Low Gain

 
 

Version history

Time Author Change comment
30. Mar 2022 18:55:02 CEST seifen Updated cosmis calibration results via API.
13. Aug 2018 11:39:10 CEST mario Assigned to submodule by script
13. Aug 2018 10:35:53 CEST mario Auto-created by unit assembly script