Temperature sensor specification:  
Serial: 1009
Submodule: 25092014-1
Position: slot 4, right (looking to IP), front (towards IP)
Calibration polynomial:
(old standard)
T ( R ) = ( -2.055e+2 ± 0.000e+0 )  °C + ( 1.157e+0 ± 0.000e+0 ) °C Ω R + ( 1.073e-2 ± 0.000e+0 ) °C Ω 2 R 2 + ( -3.092e-5 ± 0.000e+0 ) °C Ω 3 R 3
Calibration date: 01. January 2001
Broken?: No
   
Production details:  
Produced by: Cathrina
Production date: 28. September 2017
R at room temperature: 117.3 Ω
   
Notes:


Calibration Polynomials

Measurement Calibration Dataset Dataset Type
There are no calibration measurements linked to this sensor!


Version history

Time Author Change comment
02. Mar 2023 13:33:15 CET fhoelzken Updated sensor calibration via API.
14. May 2021 09:01:38 CEST oafedulidis
01. Aug 2018 13:53:19 CEST petra