RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show temperature sensor 1661


This is all the information about the temperature sensor 1661. If it is wrong, edit the data.


Attention: The calibration formula display below is written in MathML and optimized for Mozilla Firefox. If you cannot see it properly or your browser does not support MathML, use Firefox.

Temperature sensor specification:  
Serial: 1661
Submodule: none
Position: none
Calibration polynomial:
(old standard)
T ( R ) = ( -2.007e+2 ± 0.000e+0 )  °C + ( 1.045e+0 ± 0.000e+0 ) °C Ω R + ( 1.132e-2 ± 0.000e+0 ) °C Ω 2 R 2 + ( -3.189e-5 ± 0.000e+0 ) °C Ω 3 R 3
Calibration date: 01. January 1970
Broken?: Yes
   
Production details:  
Produced by: Vincent
Production date: 19. August 2019
R at room temperature: 117.4 Ω
   
Notes: 2019-08-19 08:31 a printed, 2019-08-21 08:59 glued, 14:27-14:40 baked


Calibration Polynomials

Measurement Calibration Dataset Dataset Type
There are no calibration measurements linked to this sensor!


Version history

Time Author Change comment
02. Mar 2023 13:34:25 CET fhoelzken Updated sensor calibration via API.
20. Nov 2020 15:44:52 CET aathanassiadis Broken by building module
13. Oct 2020 09:31:07 CEST jreher
04. Sep 2019 13:08:40 CEST miriamk