RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show temperature sensor 1536


This is all the information about the temperature sensor 1536. If it is wrong, edit the data.


Attention: The calibration formula display below is written in MathML and optimized for Mozilla Firefox. If you cannot see it properly or your browser does not support MathML, use Firefox.

Temperature sensor specification:  
Serial: 1536
Submodule: 20102014-2
Position: slot E, bottom, back (towards backplate)
Calibration polynomial:
(old standard)
T ( R ) = ( -1.966e+2 ± 0.000e+0 )  °C + ( 9.292e-1 ± 0.000e+0 ) °C Ω R + ( 1.298e-2 ± 0.000e+0 ) °C Ω 2 R 2 + ( -3.773e-5 ± 0.000e+0 ) °C Ω 3 R 3
Calibration date: 01. January 1970
Broken?: No
   
Production details:  
Produced by: Vincent
Production date: 09. August 2019
R at room temperature: 115.6 Ω
   
Notes: 2019-08-07 09:19 b printed, first loop shorter, 2019-08-09 10:55 glued, 14:35-14:51 baked


Calibration Polynomials

Measurement Calibration Dataset Dataset Type
There are no calibration measurements linked to this sensor!


Version history

Time Author Change comment
02. Mar 2023 13:34:04 CET fhoelzken Updated sensor calibration via API.
13. Oct 2020 09:27:49 CEST jreher
16. Aug 2019 16:03:42 CEST miriamk