RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show temperature sensor 1350


This is all the information about the temperature sensor 1350. If it is wrong, edit the data.


Attention: The calibration formula display below is written in MathML and optimized for Mozilla Firefox. If you cannot see it properly or your browser does not support MathML, use Firefox.

Temperature sensor specification:  
Serial: 1350
Submodule: 22012015-6
Position: slot 0, right (looking to IP), front (towards IP)
Calibration polynomial:
(old standard)
T ( R ) = ( -1.150e+2 ± 0.000e+0 )  °C + ( -1.399e+0 ± 0.000e+0 ) °C Ω R + ( 3.621e-2 ± 0.000e+0 ) °C Ω 2 R 2 + ( -1.128e-4 ± 0.000e+0 ) °C Ω 3 R 3
Calibration date: 01. January 1970
Broken?: No
   
Production details:  
Produced by: Vincent
Production date: 26. July 2019
R at room temperature: 112.9 Ω
   
Notes: 2019-07-16 14:28 c printed, 2019-07-26 09:51 glued, baking time 7min


Calibration Polynomials

Measurement Calibration Dataset Dataset Type
There are no calibration measurements linked to this sensor!


Version history

Time Author Change comment
02. Mar 2023 13:33:39 CET fhoelzken Updated sensor calibration via API.
15. Nov 2022 13:46:31 CET oafedulidis
16. Aug 2019 11:11:37 CEST petra
14. Aug 2019 10:45:36 CEST petra