Show temperature sensor 1304


This is all the information about the temperature sensor 1304. If it is wrong, edit the data.


Attention: The calibration formula display below is written in MathML and optimized for Mozilla Firefox. If you cannot see it properly or your browser does not support MathML, use Firefox.

Temperature sensor specification:  
Serial: 1304
Submodule: 1-5-2014_1
Position: slot E, bottom, back (towards backplate)
Calibration polynomial:
(old standard)
T ( R ) = ( -2.093e+2 ± 0.000e+0 )  °C + ( 1.400e+0 ± 0.000e+0 ) °C Ω R + ( 1.045e-2 ± 0.000e+0 ) °C Ω 2 R 2 + ( -3.100e-5 ± 0.000e+0 ) °C Ω 3 R 3
Calibration date: 01. January 1970
Broken?: No
   
Production details:  
Produced by: Vincent
Production date: 15. July 2019
R at room temperature: 109.2 Ω
   
Notes: 2019-07-12 14:47 b printed, 2019-07-16 08:27 glued, 10:30-10:40 baked


Calibration Polynomials

Measurement Calibration Dataset Dataset Type
There are no calibration measurements linked to this sensor!


Version history

Time Author Change comment
02. Mar 2023 13:33:36 CET fhoelzken Updated sensor calibration via API.
03. Sep 2020 12:32:08 CEST jreher
29. Jul 2019 14:12:39 CEST miriamk