Show Hamamatsu Avalanche Photo Diode 1603016930 - Archived data from Wed, 21. April 2021 12:51:24 CEST
This is all the information about APD 1603016930. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1603016930 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | G07 |
| Break-through voltage: | 414 V |
| Voltage for Gain 100 (T=+25°C): | 387.6 V |
| Dark current: | 6.7 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 302 |
| Position in Box: | 12 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 435 |
| Position in grid: | 6 |
| Arrival for irradiation: | 30. Oct 2017 |
| Sent for analysis after irradiation: | 10. Nov 2017 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 10. Nov 2017 |
| Dose used: | 45 Gy |
| Temperature: | 20 °C |
| Position: | 3 |
| Bias voltage: | 387.6 V (connected) |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 389.0015632 V T = -25 °C: 351.0047146 V |
| Voltage for Gain 150: | T = +20 °C: 396.9564401 V T = -25 °C: 358.3382491 V |
| Voltage for Gain 200: | T = +20 °C: 401.3761154 V T = -25 °C: 363.4240606 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.569410544 V-1 T = -25 °C: 13.07631167 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.954242902 V-1 T = -25 °C: 23.34718711 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 13.84525729 V-1 T = -25 °C: 24.47821674 V-1 |
| Break-through voltage: | T = +20 °C: 416.9241214 V T = -25 °C: 380.1708381 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 26. Oct 2021 10:45:48 CEST | oafedulidis | Assigned to capsule by script |
| 17. May 2021 09:15:50 CEST | oafedulidis | Updated box and position via API. |
| 21. Apr 2021 12:51:24 CEST | jreher | Updated box and position via API. |
| 05. Feb 2021 11:29:55 CET | jreher | Updated box and position via API. |
| 05. Feb 2021 11:27:15 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 18:10:29 CEST | jreher | Updated APD characteristics via API. |
| 11. Aug 2020 17:57:28 CEST | jreher | Updated APD characteristics via API. |
| 21. Jul 2020 16:15:59 CEST | jreher | Updated APD batch assignment via API. |
| 21. Jul 2020 14:43:24 CEST | jreher | Updated APD location via API. |
| 21. Jul 2020 14:43:14 CEST | jreher | Updated box and position via API. |
| 19. Dec 2019 16:18:43 CET | spankonin | Updated APD batch assignment via API. |
| 19. Dec 2019 15:18:05 CET | jreher | Updated box and position via API. |
| 10. Nov 2017 09:39:35 CET | markus.moritz | Entered shipped after irradiation date. |
| 10. Nov 2017 09:38:03 CET | markus.moritz | Entered irradiation information. |
| 09. Nov 2017 15:11:38 CET | markus.moritz | Entered arrival for irradiation date. |
| 02. Nov 2017 15:16:55 CET | Tobias | Assigned to grid via information extracted from APD DB. |
| 23. Jun 2016 10:42:21 CEST | Tobias | Imported from Hamamatsu datasheet. |