RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1602016816 - Archived data from Tue, 11. August 2020 17:27:16 CEST


This is all the information about APD 1602016816. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1602016816
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 1602016816/1502016570
Unit: #866 (barcode 1309009497)
Preamp: 4439
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: C03
Break-through voltage: 416 V
Voltage for Gain 100 (T=+25°C): 388 V
Dark current: 6.9 nA
   
Screening Logistics:  
Available: No
Storage Box: 46
Position in Box: 23
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 430
Position in grid: 17
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 16. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 29. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 30. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 387.8538643 V     T = -25 °C: 351.7514919 V
Voltage for Gain 150: T = +20 °C: 395.8643011 V     T = -25 °C: 359.3996904 V
Voltage for Gain 200: T = +20 °C: 400.2972483 V     T = -25 °C: 363.6412781 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.785912471 V-1     T = -25 °C: 4.719424728 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.428307754 V-1     T = -25 °C: 8.222621593 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.21902869 V-1     T = -25 °C: 16.33144524 V-1
Break-through voltage: T = +20 °C: 415.6117933 V     T = -25 °C: 379.1019066 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:54:08 CET jreher Updated box and position via API.
03. Feb 2021 18:19:53 CET jreher Updated box and position via API.
11. Aug 2020 17:27:16 CEST jreher Updated APD characteristics via API.
13. Feb 2020 14:42:52 CET jreher Updated box and position via API.
27. Nov 2019 19:37:09 CET jreher Updated APD location via API.
25. Nov 2019 17:14:33 CET jreher Updated box and position via API.
17. Oct 2019 14:11:15 CEST tholtmann Assigned to unit by script
17. Oct 2019 13:58:08 CEST tholtmann Assigned to capsule by script
04. Jul 2019 11:11:53 CEST jreher Updated APD location via API.
18. Jun 2019 13:30:07 CEST jgrochowski Updated APD batch assignment via API.
18. Jan 2019 14:43:17 CET markus.moritz
03. Dec 2018 14:04:17 CET markus.moritz
29. Sep 2017 12:32:45 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:54 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:42:19 CEST Tobias Imported from Hamamatsu datasheet.