Show Hamamatsu Avalanche Photo Diode 1601016795 - Archived data from Tue, 11. August 2020 17:26:08 CEST
This is all the information about APD 1601016795. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1601016795 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | D12 |
| Break-through voltage: | 425 V |
| Voltage for Gain 100 (T=+25°C): | 396.4 V |
| Dark current: | 5.3 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 40 |
| Position in Box: | 2 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 428 |
| Position in grid: | 16 |
| Arrival for irradiation: | 29. Sep 2017 |
| Sent for analysis after irradiation: | 26. Nov 2018 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 22. Nov 2018 |
| Dose used: | 37 Gy |
| Temperature: | 20 °C |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | 23. Nov 2018 |
| Temperature: | 80 °C |
| Duration: | 48 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 396.8103028 V T = -25 °C: 360.1881895 V |
| Voltage for Gain 150: | T = +20 °C: 404.7760731 V T = -25 °C: 368.0097477 V |
| Voltage for Gain 200: | T = +20 °C: 409.1955602 V T = -25 °C: 372.4011343 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.44039764 V-1 T = -25 °C: 4.430761037 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.471988946 V-1 T = -25 °C: 9.211654864 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 14.15357928 V-1 T = -25 °C: 13.91154683 V-1 |
| Break-through voltage: | T = +20 °C: 424.8094169 V T = -25 °C: 388.3102076 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 10:53:20 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:19:06 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:26:08 CEST | jreher | Updated APD characteristics via API. |
| 27. Nov 2019 19:36:03 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:14:02 CET | jreher | Updated box and position via API. |
| 04. Jul 2019 11:11:01 CEST | jreher | Updated APD location via API. |
| 12. Jun 2019 16:48:22 CEST | jreher | Updated APD batch assignment via API. |
| 12. Jun 2019 16:33:17 CEST | jreher | Updated APD batch assignment via API. |
| 26. Nov 2018 15:01:17 CET | markus.moritz | |
| 29. Sep 2017 13:46:17 CEST | markus.moritz | Entered arrival for irradiation date. |
| 01. Aug 2016 17:29:52 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 23. Jun 2016 10:42:19 CEST | Tobias | Imported from Hamamatsu datasheet. |