Show Hamamatsu Avalanche Photo Diode 1601016778 - Archived data from Wed, 07. October 2020 15:45:54 CEST
					This is all the information about APD 1601016778. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1601016778 | 
| Type: | Hamamatsu Avalanche Photo Diode | 
| Detector: | unassigned | 
| Unit: | unassigned | 
| Preamp: | 0 | 
| Current location: | In transit to Mainz | 
| Installation information: | |
| Label: | none | 
| Manufacturer information: | |
| Wafer position: | C02 | 
| Break-through voltage: | 410 V | 
| Voltage for Gain 100 (T=+25°C): | 382 V | 
| Dark current: | 5.7 nA | 
| Screening Logistics: | |
| Available: | Yes | 
| Storage Box: | 35 | 
| Position in Box: | 5 | 
| EP1 batch: | none | 
| EP1 batch after irradiation: | none | 
| Shipment: | |
| Grid number: | 428 | 
| Position in grid: | 0 | 
| Arrival for irradiation: | 29. Sep 2017 | 
| Sent for analysis after irradiation: | 26. Nov 2018 | 
| Return for assembly: | none | 
| Irradiation: | |
| Date: | 22. Nov 2018 | 
| Dose used: | 37 Gy | 
| Temperature: | 20 °C | 
| Position: | none | 
| Bias voltage: | none | 
| Annealing: | |
| Date: | 23. Nov 2018 | 
| Temperature: | 80 °C | 
| Duration: | 48 h | 
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 382.7401438 V T = -25 °C: 346.8576283 V | 
| Voltage for Gain 150: | T = +20 °C: 390.6576534 V T = -25 °C: 354.3048916 V | 
| Voltage for Gain 200: | T = +20 °C: 395.057255 V T = -25 °C: 358.501944 V | 
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.396956846 V-1 T = -25 °C: 4.938137738 V-1 | 
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.957380587 V-1 T = -25 °C: 9.494151597 V-1 | 
| Gain/Voltage slope at M = 200: | T = +20 °C: 14.15624859 V-1 T = -25 °C: 15.19804331 V-1 | 
| Break-through voltage: | T = +20 °C: 408.8921717 V T = -25 °C: 372.0291562 V | 
| Notes: | 
						
					
Version history
| Time | Author | Change comment | 
|---|---|---|
| 05. Feb 2021 10:52:23 CET | jreher | Updated box and position via API. | 
| 03. Feb 2021 18:18:26 CET | jreher | Updated box and position via API. | 
| 07. Oct 2020 15:45:54 CEST | jreher | Updated APD location via API. | 
| 11. Aug 2020 17:25:19 CEST | jreher | Updated APD characteristics via API. | 
| 28. Nov 2019 12:22:47 CET | jreher | Updated APD location via API. | 
| 25. Nov 2019 17:13:37 CET | jreher | Updated box and position via API. | 
| 13. Jun 2019 11:29:28 CEST | jreher | Updated APD location via API. | 
| 12. Jun 2019 16:47:59 CEST | jreher | Updated APD batch assignment via API. | 
| 12. Jun 2019 16:32:55 CEST | jreher | Updated APD batch assignment via API. | 
| 26. Nov 2018 15:13:02 CET | markus.moritz | |
| 29. Sep 2017 13:46:17 CEST | markus.moritz | Entered arrival for irradiation date. | 
| 01. Aug 2016 17:29:52 CEST | Tobias | Assigned to grid via information extracted from APD DB. | 
| 23. Jun 2016 10:42:18 CEST | Tobias | Imported from Hamamatsu datasheet. | 
 
						 
					