Show Hamamatsu Avalanche Photo Diode 1402015240 - Archived data from Tue, 11. August 2020 17:58:27 CEST
This is all the information about APD 1402015240. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1402015240 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | G11 |
| Break-through voltage: | 427 V |
| Voltage for Gain 100 (T=+25°C): | 399 V |
| Dark current: | 6.1 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 307 |
| Position in Box: | 48 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 363 |
| Position in grid: | 9 |
| Arrival for irradiation: | 29. Sep 2017 |
| Sent for analysis after irradiation: | 03. Nov 2017 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 26. Oct 2017 |
| Dose used: | 45 Gy |
| Temperature: | 20 °C |
| Position: | 2 |
| Bias voltage: | 399 V (connected) |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 399.8737233 V T = -25 °C: 363.3320103 V |
| Voltage for Gain 150: | T = +20 °C: 407.778939 V T = -25 °C: 371.0786034 V |
| Voltage for Gain 200: | T = +20 °C: 412.1581803 V T = -25 °C: 375.408409 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.600142697 V-1 T = -25 °C: 4.568231606 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 9.103166543 V-1 T = -25 °C: 8.948046442 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 14.14458581 V-1 T = -25 °C: 15.80538437 V-1 |
| Break-through voltage: | T = +20 °C: 424.5135411 V T = -25 °C: 390.7530932 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 11:28:07 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:58:27 CEST | jreher | Updated APD characteristics via API. |
| 21. Jul 2020 14:44:42 CEST | jreher | Updated APD location via API. |
| 21. Jul 2020 14:44:32 CEST | jreher | Updated box and position via API. |
| 19. Dec 2019 16:36:08 CET | spankonin | Updated APD batch assignment via API. |
| 19. Dec 2019 15:18:47 CET | jreher | Updated box and position via API. |
| 03. Nov 2017 16:13:01 CET | markus.moritz | Entered shipped after irradiation date. |
| 26. Oct 2017 16:36:09 CEST | markus.moritz | Entered irradiation information. |
| 29. Sep 2017 11:34:21 CEST | markus.moritz | Entered arrival for irradiation date. |
| 01. Aug 2016 17:29:07 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 23. Jun 2016 10:31:18 CEST | Tobias | Imported from Hamamatsu datasheet. |