Show Hamamatsu Avalanche Photo Diode 1320015058
This is all the information about APD 1320015058. If it is wrong, edit the data.
| Subdetector specification: |
|
| Serial: |
1320015058 |
| Type: |
Hamamatsu Avalanche Photo Diode |
| Detector: |
unassigned |
| Unit: |
unassigned |
| Preamp: |
0 |
| Current location: |
Bochum |
| |
|
| Installation information: |
|
| Label: |
none |
| |
|
| Manufacturer information: |
|
| Wafer position: |
E02 |
| Break-through voltage: |
445 V |
| Voltage for Gain 100 (T=+25°C): |
416 V |
| Dark current: |
5.5 nA |
| |
|
| Screening Logistics: |
|
| Available: |
Yes |
| Storage Box: |
356 |
| Position in Box: |
42 |
| EP1 batch: |
none |
| EP1 batch after irradiation: |
10542 |
| |
|
| Shipment: |
|
| Grid number: |
354 |
| Position in grid: |
16 |
| Arrival for irradiation: |
29. Sep 2017 |
| Sent for analysis after irradiation: |
20. Oct 2017 |
| Return for assembly: |
none |
| |
|
| Irradiation: |
|
| Date: |
19. Oct 2017 |
| Dose used: |
45 Gy |
| Temperature: |
20 °C |
| Position: |
4 |
| Bias voltage: |
416 V (connected) |
| |
|
| Annealing: |
|
| Date: |
none |
| Temperature: |
none |
| Duration: |
none |
| |
|
| Measurement results: |
|
| Voltage for Gain 100: |
T = +20 °C: 417.9320951 V T = -25 °C: 380.339535 V |
| Voltage for Gain 150: |
T = +20 °C: 425.955818 V T = -25 °C: 388.399 V |
| Voltage for Gain 200: |
T = +20 °C: 430.5887647 V T = -25 °C: 392.8471358 V |
| Gain/Voltage slope at M = 100: |
T = +20 °C: 4.62337817 V-1 T = -25 °C: 4.38941672 V-1 |
| Gain/Voltage slope at M = 150: |
T = +20 °C: 8.948165663 V-1 T = -25 °C: 8.422607695 V-1 |
| Gain/Voltage slope at M = 200: |
T = +20 °C: 15.21746267 V-1 T = -25 °C: 13.99494343 V-1 |
| Break-through voltage: |
T = +20 °C: 439.936314 V T = -25 °C: 407.4105914 V |
| |
|
| Notes: |
|
Characteristics
| Temperature |
Measurement |
Notes |
| No characteristics available! |