Show Hamamatsu Avalanche Photo Diode 0902009188
This is all the information about APD 0902009188. If it is wrong, edit the data.
| Subdetector specification: |
|
| Serial: |
0902009188 |
| Type: |
Hamamatsu Avalanche Photo Diode |
| Detector: |
assigned to 0902009188/0902009176 |
| Unit: |
#2331 (barcode 1309027149) |
| Preamp: |
0 |
| Current location: |
Bochum |
| |
|
| Installation information: |
|
| Label: |
blue |
| |
|
| Manufacturer information: |
|
| Wafer position: |
F10 |
| Break-through voltage: |
406 V |
| Voltage for Gain 100 (T=+25°C): |
378.3 V |
| Dark current: |
8.7 nA |
| |
|
| Screening Logistics: |
|
| Available: |
No |
| Storage Box: |
56 |
| Position in Box: |
1 |
| EP1 batch: |
none |
| EP1 batch after irradiation: |
10083 |
| |
|
| Shipment: |
|
| Grid number: |
none |
| Position in grid: |
none |
| Arrival for irradiation: |
18. Apr 2019 |
| Sent for analysis after irradiation: |
04. Jun 2019 |
| Return for assembly: |
none |
| |
|
| Irradiation: |
|
| Date: |
29. May 2019 |
| Dose used: |
37 Gy |
| Temperature: |
20 °C |
| Position: |
none |
| Bias voltage: |
none |
| |
|
| Annealing: |
|
| Date: |
29. May 2019 |
| Temperature: |
80 °C |
| Duration: |
48 h |
| |
|
| Measurement results: |
|
| Voltage for Gain 100: |
T = +20 °C: 378.2900368 V T = -25 °C: 342.7384368 V |
| Voltage for Gain 150: |
T = +20 °C: 386.1002706 V T = -25 °C: 350.0593764 V |
| Voltage for Gain 200: |
T = +20 °C: 390.4599769 V T = -25 °C: 354.1713761 V |
| Gain/Voltage slope at M = 100: |
T = +20 °C: 4.519780586 V-1 T = -25 °C: 4.956077125 V-1 |
| Gain/Voltage slope at M = 150: |
T = +20 °C: 9.112099966 V-1 T = -25 °C: 9.631415176 V-1 |
| Gain/Voltage slope at M = 200: |
T = +20 °C: 15.38200454 V-1 T = -25 °C: 14.64771189 V-1 |
| Break-through voltage: |
T = +20 °C: 405.3581892 V T = -25 °C: 368.9168805 V |
| |
|
| Notes: |
Wrong wafer number in serial number, correct wafer number is 3.
|
Characteristics
| Temperature |
Measurement |
Notes |
| No characteristics available! |
Upload new characteristic...
Progression of the current during irradiation
| Upload time |
Notes |
| No data available! |
Upload new progression data...
Version history