RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0822008946 - Archived data from Tue, 11. August 2020 17:36:52 CEST


This is all the information about APD 0822008946. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0822008946
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G12
Break-through voltage: 420 V
Voltage for Gain 100 (T=+25°C): 392.3 V
Dark current: 5.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 197
Position in Box: 39
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 392.3066568 V     T = -25 °C: 356.1364831 V
Voltage for Gain 150: T = +20 °C: 400.2573718 V     T = -25 °C: 363.839849 V
Voltage for Gain 200: T = +20 °C: 404.6508315 V     T = -25 °C: 368.1708737 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.404544822 V-1     T = -25 °C: 4.637125599 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.58929497 V-1     T = -25 °C: 9.112629983 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.84049151 V-1     T = -25 °C: 14.08700962 V-1
Break-through voltage: T = +20 °C: 420.0789595 V     T = -25 °C: 383.9370238 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:13:50 CET jreher Updated box and position via API.
11. Aug 2020 17:36:52 CEST jreher Updated APD characteristics via API.
27. Nov 2019 20:03:58 CET jreher Updated APD location via API.
25. Nov 2019 17:26:25 CET jreher Updated box and position via API.
13. Aug 2019 14:51:45 CEST spankonin Updated APD batch assignment via API.
22. Jun 2016 15:29:43 CEST Tobias Imported from Hamamatsu datasheet.