RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3205034907 - Archived data from Tue, 11. August 2020 18:08:18 CEST


This is all the information about APD 3205034907. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3205034907
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E11
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.6 V
Dark current: 27.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 135
Position in Box: 32
EP1 batch: 154
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.8061861 V     T = -25 °C: 346.2183828 V
Voltage for Gain 150: T = +20 °C: 389.6315494 V     T = -25 °C: 353.5419322 V
Voltage for Gain 200: T = +20 °C: 393.9466733 V     T = -25 °C: 357.6766218 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.976337778 V-1     T = -25 °C: 4.905840896 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.730454514 V-1     T = -25 °C: 9.022134057 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.16144753 V-1     T = -25 °C: 16.01411896 V-1
Break-through voltage: T = +20 °C: 409.5765755 V     T = -25 °C: 373.0353546 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:05:44 CET jreher Updated box and position via API.
11. Aug 2020 18:08:18 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:57 CEST jreher Updated APD location via API.
09. Mar 2020 17:39:02 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:19 CET jreher Updated APD location via API.
27. Nov 2019 19:52:39 CET jreher Updated APD location via API.
25. Nov 2019 17:21:37 CET jreher Updated box and position via API.
20. Sep 2019 18:43:37 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:54:18 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:54 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:18 CEST Tobias Imported from Hamamatsu datasheet.