RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3009033771


This is all the information about APD 3009033771. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3009033771
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2507028015/3009033771
Unit: #2995 (barcode 1309033805)
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: D09
Break-through voltage: 414 V
Voltage for Gain 100 (T=+25°C): 385.5 V
Dark current: 20.8 nA
   
Screening Logistics:  
Available: No
Storage Box: 119
Position in Box: 3
EP1 batch: 127
EP1 batch after irradiation: 10465
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 24. Jul 2018
Sent for analysis after irradiation: 21. Aug 2018
Return for assembly: none
   
Irradiation:  
Date: 16. Aug 2018
Dose used: 30 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Aug 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.716896 V     T = -25 °C: 350.7152564 V
Voltage for Gain 150: T = +20 °C: 393.5390342 V     T = -25 °C: 358.2235546 V
Voltage for Gain 200: T = +20 °C: 397.8680025 V     T = -25 °C: 362.5350244 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.725894994 V-1     T = -25 °C: 5.029659085 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.549697654 V-1     T = -25 °C: 8.846368456 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.89651983 V-1     T = -25 °C: 15.14757014 V-1
Break-through voltage: T = +20 °C: 414.4185759 V     T = -25 °C: 376.5734705 V
   
Notes: foam


Characteristics

Temperature Measurement Notes
No characteristics available!


Upload new characteristic...

Progression of the current during irradiation

Upload time Notes
No data available!


Upload new progression data...

Version history

Time Author Change comment
19. Nov 2021 13:05:37 CET oafedulidis Assigned to capsule by script
16. Jun 2021 16:04:41 CEST oafedulidis Updated box and position via API.
16. Jun 2021 16:00:52 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:53:37 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:03:42 CET jreher Updated box and position via API.
11. Aug 2020 18:07:16 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:49:43 CEST jreher Updated APD location via API.
02. Mar 2020 16:40:46 CET vwerner Updated APD batch assignment via API.
29. Nov 2019 11:47:19 CET jreher Updated APD location via API.
27. Nov 2019 19:49:42 CET jreher Updated APD location via API.
25. Nov 2019 17:20:21 CET jreher Updated box and position via API.
30. Aug 2019 11:27:49 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:52:11 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:28 CET Tobias Corrected dark current unit.
21. Aug 2018 10:40:08 CEST markus.moritz
06. Jul 2018 22:38:51 CEST Tobias Imported from Hamamatsu datasheet.