Show Hamamatsu Avalanche Photo Diode 2608029762 - Archived data from Thu, 13. June 2019 10:01:14 CEST
This is all the information about APD 2608029762. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 2608029762 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | H07 |
| Break-through voltage: | 407 V |
| Voltage for Gain 100 (T=+25°C): | 380.6 V |
| Dark current: | 9.9 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 44 |
| Position in Box: | 42 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | none |
| Position in grid: | none |
| Arrival for irradiation: | 24. Jul 2018 |
| Sent for analysis after irradiation: | 21. Aug 2018 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 16. Aug 2018 |
| Dose used: | 30 Gy |
| Temperature: | 20 °C |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | 17. Aug 2018 |
| Temperature: | 80 °C |
| Duration: | 48 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
| Break-through voltage: | T = +20 °C: none T = -25 °C: none |
| Notes: | foam |
Version history
| Time | Author | Change comment |
|---|---|---|
| 10. Jun 2022 12:16:18 CEST | oafedulidis | Assigned to capsule by script |
| 03. May 2021 15:18:37 CEST | oafedulidis | Updated box and position via API. |
| 22. Feb 2021 11:10:51 CET | jreher | Updated box and position via API. |
| 05. Feb 2021 10:57:20 CET | jreher | Updated box and position via API. |
| 05. Feb 2021 10:53:53 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:22:53 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:19:41 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:26:55 CEST | jreher | Updated APD characteristics via API. |
| 04. Aug 2020 15:48:20 CEST | jreher | Updated box and position via API. |
| 27. Nov 2019 19:36:50 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:16:25 CET | jreher | Updated box and position via API. |
| 25. Nov 2019 17:14:26 CET | jreher | Updated box and position via API. |
| 04. Jul 2019 11:11:37 CEST | jreher | Updated APD location via API. |
| 13. Jun 2019 10:01:14 CEST | jreher | Updated APD batch assignment via API. |
| 03. Jan 2019 00:13:06 CET | Tobias | Corrected dark current unit. |
| 21. Aug 2018 11:57:36 CEST | markus.moritz | |
| 24. May 2018 14:39:23 CEST | Tobias | Updated location to "Bochum". |
| 18. May 2018 12:00:57 CEST | Tobias | Imported from Hamamatsu datasheet. |