Show Hamamatsu Avalanche Photo Diode 2404026177 - Archived data from Wed, 16. June 2021 16:03:54 CEST


This is all the information about APD 2404026177. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2404026177
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D04
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.5 V
Dark current: 5.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 255
Position in Box: 48
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Sep 2018
Sent for analysis after irradiation: 02. Oct 2018
Return for assembly: none
   
Irradiation:  
Date: 27. Sep 2018
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: 28. Sep 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.3623882 V     T = -25 °C: 346.0383034 V
Voltage for Gain 150: T = +20 °C: 389.2498066 V     T = -25 °C: 353.4445865 V
Voltage for Gain 200: T = +20 °C: 393.6824575 V     T = -25 °C: 357.6145815 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.454130677 V-1     T = -25 °C: 4.789345067 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.813913678 V-1     T = -25 °C: 9.276258025 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.37919755 V-1     T = -25 °C: 16.49319579 V-1
Break-through voltage: T = +20 °C: 409.4773424 V     T = -25 °C: 373.1688269 V
   
Notes:


Version history

Time Author Change comment
27. Jun 2022 12:42:41 CEST oafedulidis Assigned to capsule by script
16. Jun 2021 16:03:54 CEST oafedulidis Updated box and position via API.
16. Jun 2021 16:00:10 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:52:50 CEST oafedulidis Updated box and position via API.
26. Apr 2021 15:21:18 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:48:38 CET jreher Updated box and position via API.
03. Feb 2021 18:14:50 CET jreher Updated box and position via API.
11. Aug 2020 17:20:57 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:30:38 CET jreher Updated APD location via API.
25. Nov 2019 17:11:28 CET jreher Updated box and position via API.
04. Jul 2019 11:05:47 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:57 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:52 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:01:20 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:48 CET Tobias Corrected dark current unit.
02. Oct 2018 13:35:24 CEST markus.moritz
26. Sep 2018 12:03:36 CEST markus.moritz