Subdetector specification:  
Serial: 2404026177
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 3107034311/2404026177
Unit: #3480 (barcode 1309038770)
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: D04
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.5 V
Dark current: 5.1 nA
   
Screening Logistics:  
Available: No
Storage Box: 255
Position in Box: 48
EP1 batch: none
EP1 batch after irradiation: 10012
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Sep 2018
Sent for analysis after irradiation: 02. Oct 2018
Return for assembly: none
   
Irradiation:  
Date: 27. Sep 2018
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: 28. Sep 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.3623882 V     T = -25 °C: 346.0383034 V
Voltage for Gain 150: T = +20 °C: 389.2498066 V     T = -25 °C: 353.4445865 V
Voltage for Gain 200: T = +20 °C: 393.6824575 V     T = -25 °C: 357.6145815 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.454130677 V-1     T = -25 °C: 4.789345067 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.813913678 V-1     T = -25 °C: 9.276258025 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.37919755 V-1     T = -25 °C: 16.49319579 V-1
Break-through voltage: T = +20 °C: 409.4773424 V     T = -25 °C: 373.1688269 V
   
Notes:


Characteristics

Temperature Measurement Notes
No characteristics available!


Upload new characteristic...

Progression of the current during irradiation

Upload time Notes
No data available!


Upload new progression data...

Version history

Time Author Change comment
27. Jun 2022 12:42:41 CEST oafedulidis Assigned to capsule by script
16. Jun 2021 16:03:54 CEST oafedulidis Updated box and position via API.
16. Jun 2021 16:00:10 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:52:50 CEST oafedulidis Updated box and position via API.
26. Apr 2021 15:21:18 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:48:38 CET jreher Updated box and position via API.
03. Feb 2021 18:14:50 CET jreher Updated box and position via API.
11. Aug 2020 17:20:57 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:30:38 CET jreher Updated APD location via API.
25. Nov 2019 17:11:28 CET jreher Updated box and position via API.
04. Jul 2019 11:05:47 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:57 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:52 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:01:20 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:48 CET Tobias Corrected dark current unit.
02. Oct 2018 13:35:24 CEST markus.moritz
26. Sep 2018 12:03:36 CEST markus.moritz
12. Jan 2018 13:16:49 CET Tobias Imported from Hamamatsu datasheet.