RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2404026155


This is all the information about APD 2404026155. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2404026155
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2404026155/2708030585
Unit: #2896 (barcode 1309032174)
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: E07
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 379.5 V
Dark current: 3.5 nA
   
Screening Logistics:  
Available: No
Storage Box: 40
Position in Box: 32
EP1 batch: none
EP1 batch after irradiation: 10065
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Sep 2018
Sent for analysis after irradiation: 02. Oct 2018
Return for assembly: none
   
Irradiation:  
Date: 27. Sep 2018
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: 28. Sep 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.4808784 V     T = -25 °C: 344.5496037 V
Voltage for Gain 150: T = +20 °C: 387.2946185 V     T = -25 °C: 351.8180699 V
Voltage for Gain 200: T = +20 °C: 391.6729394 V     T = -25 °C: 355.946054 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.042375428 V-1     T = -25 °C: 4.522445453 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.919953343 V-1     T = -25 °C: 8.951444311 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.71240815 V-1     T = -25 °C: 15.00799386 V-1
Break-through voltage: T = +20 °C: 407.681289 V     T = -25 °C: 371.5748258 V
   
Notes: sent to Bochum on 26_11_2018


Characteristics

Temperature Measurement Notes
No characteristics available!


Upload new characteristic...

Progression of the current during irradiation

Upload time Notes
No data available!


Upload new progression data...

Version history

Time Author Change comment
16. Nov 2021 09:41:58 CET oafedulidis Assigned to capsule by script
16. Jun 2021 16:02:38 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:58:56 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:51:45 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:53:23 CET jreher Updated box and position via API.
05. Feb 2021 10:48:33 CET jreher Updated box and position via API.
03. Feb 2021 18:19:09 CET jreher Updated box and position via API.
03. Feb 2021 18:14:47 CET jreher Updated box and position via API.
11. Aug 2020 17:26:15 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:30:37 CET jreher Updated APD location via API.
25. Nov 2019 17:14:04 CET jreher Updated box and position via API.
25. Nov 2019 17:11:27 CET jreher Updated box and position via API.
04. Jul 2019 11:05:46 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:24 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:20 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:48 CET Tobias Corrected dark current unit.
27. Nov 2018 15:02:42 CET markus.moritz
02. Oct 2018 13:50:52 CEST markus.moritz
26. Sep 2018 11:55:38 CEST markus.moritz
12. Jan 2018 13:16:48 CET Tobias Imported from Hamamatsu datasheet.