Grid Overview
| Grid specification: | |
|---|---|
| Grid number: | 306 |
| Number of APDs: | 19 |
| Grid information: | |
| Arrival for irradiation: | 27. Oct 2016 |
| Date of irradiation: | 31. Oct 2016 |
| Irradiation temperature: | 20 °C |
| Irradiation voltage: | 350 V |
| Irradiation dose: | 30 Gy |
| Irradiation position: | 1 |
| Shipped for annealing/analysis: | 02. Nov 2016 |
| Annealing date: | none |
| Annealing temperature: | none |
| Annealing duration: | none |
| Return for assembly: | 20. Dec 2016 |
| Operations: | Enter irradiation data • Enter annealing data • Enter shipment data |
| Grid overview: | |
| Slot 0: | 1306013950 (HV connected) |
| Slot 1: | 1306013939 (HV connected) |
| Slot 2: | 1306013951 (HV connected) |
| Slot 3: | 1306013940 (HV connected) |
| Slot 4: | 1306013952 (HV connected) |
| Slot 5: | 1306013941 (HV connected) |
| Slot 6: | 1306013953 (HV connected) |
| Slot 7: | 1306013943 (HV connected) |
| Slot 8: | 1306013954 (HV connected) |
| Slot 9: | 1306013944 (HV not connected) |
| Slot 10: | 1306013955 (HV connected) |
| Slot 11: | 1306013945 (HV connected) |
| Slot 12: | 1306013956 (HV connected) |
| Slot 13: | 1306013946 (HV connected) |
| Slot 14: | empty |
| Slot 15: | 1306013947 (HV connected) |
| Slot 16: | 1306013958 (HV connected) |
| Slot 17: | 1306013948 (HV connected) |
| Slot 18: | 1306013959 (HV connected) |
| Slot 19: | 1306013949 (HV connected) |