Show VPTT teststand results
| Detector specification: | |
|---|---|
| Serial: | UA0812 |
| Type: | Hamamatsu Vacuum Photo Tetrode |
| Measurement results: | |
| Amplitude: | 5180.21 ± 628.176 |
| Normalized Amplitude: | 2.13357 ± 0.869582 |
| Energy: | 21357.8 ± 1922.66 |
| Normalized Energy: | 6.62692 ± 4.23887 |
| Note: The errors given above are the RMS of the histogram from which the mean value was derived. | |
| Created: | Mon, 12. November 2018 14:39:04 CET |
| Notes: | High Gain |