Show Hamamatsu Avalanche Photo Diode 1612017702 - Archived data from Wed, 16. June 2021 15:52:01 CEST


This is all the information about APD 1612017702. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1612017702
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B07
Break-through voltage: 423 V
Voltage for Gain 100 (T=+25°C): 394.5 V
Dark current: 4.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 301
Position in Box: 10
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 465
Position in grid: 7
Arrival for irradiation: 30. Oct 2017
Sent for analysis after irradiation: 17. Nov 2017
Return for assembly: none
   
Irradiation:  
Date: 16. Nov 2017
Dose used: 45 Gy
Temperature: 20 °C
Position: 3
Bias voltage: 394.5 V     (connected)
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 394.4451602 V     T = -25 °C: 357.9270261 V
Voltage for Gain 150: T = +20 °C: 402.4323648 V     T = -25 °C: 365.6962934 V
Voltage for Gain 200: T = +20 °C: 406.8657891 V     T = -25 °C: 370.0392129 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.391893033 V-1     T = -25 °C: 4.721165113 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.512025788 V-1     T = -25 °C: 9.355437544 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.67111359 V-1     T = -25 °C: 14.56699416 V-1
Break-through voltage: T = +20 °C: 422.6963951 V     T = -25 °C: 386.0640234 V
   
Notes:


Version history

Time Author Change comment
19. Nov 2021 13:06:23 CET oafedulidis Assigned to capsule by script
16. Jun 2021 16:02:58 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:59:22 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:52:01 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:27:07 CET jreher Updated box and position via API.
11. Aug 2020 17:57:18 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:43:09 CEST jreher Updated APD location via API.
21. Jul 2020 14:42:59 CEST jreher Updated box and position via API.
19. Dec 2019 15:54:10 CET spankonin Updated APD batch assignment via API.
19. Dec 2019 15:17:57 CET jreher Updated box and position via API.
17. Nov 2017 09:39:50 CET markus.moritz Entered shipped after irradiation date.
17. Nov 2017 09:38:37 CET markus.moritz Entered irradiation information.
09. Nov 2017 15:12:20 CET markus.moritz Entered arrival for irradiation date.
02. Nov 2017 15:16:56 CET Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:45:35 CEST Tobias Imported from Hamamatsu datasheet.