Show Hamamatsu Avalanche Photo Diode 1609017478 - Archived data from Tue, 11. August 2020 17:27:09 CEST
This is all the information about APD 1609017478. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1609017478 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | D08 |
| Break-through voltage: | 420 V |
| Voltage for Gain 100 (T=+25°C): | 391.4 V |
| Dark current: | 4.8 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 46 |
| Position in Box: | 9 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 3003 |
| Position in grid: | 7 |
| Arrival for irradiation: | 11. Aug 2016 |
| Sent for analysis after irradiation: | 02. Sep 2016 |
| Return for assembly: | 13. Oct 2016 |
| Irradiation: | |
| Date: | 23. Aug 2016 |
| Dose used: | 30 Gy |
| Temperature: | 25 °C |
| Position: | 4 |
| Bias voltage: | 350 V (connected) |
| Annealing: | |
| Date: | 24. Aug 2016 |
| Temperature: | 80 °C |
| Duration: | 10 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 392.4269482 V T = -25 °C: 355.829416 V |
| Voltage for Gain 150: | T = +20 °C: 400.3676817 V T = -25 °C: 363.5010525 V |
| Voltage for Gain 200: | T = +20 °C: 404.7609753 V T = -25 °C: 367.7151178 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.63184249 V-1 T = -25 °C: 4.696905251 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.890986998 V-1 T = -25 °C: 8.924658459 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 14.30099339 V-1 T = -25 °C: 15.35872937 V-1 |
| Break-through voltage: | T = +20 °C: 419.9972048 V T = -25 °C: 383.1925475 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 10:54:05 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:19:51 CET | jreher | Updated box and position via API. |
| 07. Oct 2020 15:46:07 CEST | jreher | Updated APD location via API. |
| 11. Aug 2020 17:27:09 CEST | jreher | Updated APD characteristics via API. |
| 27. Nov 2019 19:37:08 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:14:32 CET | jreher | Updated box and position via API. |
| 04. Jul 2019 11:11:51 CEST | jreher | Updated APD location via API. |
| 18. Jun 2019 13:30:06 CEST | jgrochowski | Updated APD batch assignment via API. |
| 05. Apr 2018 14:04:16 CEST | jgrochowski | |
| 13. Oct 2016 11:49:36 CEST | markus.moritz | Entered return for assembly date. |
| 08. Sep 2016 13:36:49 CEST | markus.moritz | Entered shipped after irradiation date. |
| 24. Aug 2016 14:38:03 CEST | christopher.l.hahn | Entered irradiation information. |
| 24. Aug 2016 14:26:00 CEST | christopher.l.hahn | Entered annealing information. |
| 11. Aug 2016 11:46:23 CEST | markus.moritz | Entered arrival for irradiation date. |
| 01. Aug 2016 17:52:13 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 23. Jun 2016 10:43:34 CEST | Tobias | Imported from Hamamatsu datasheet. |