Show Hamamatsu Avalanche Photo Diode 0711006311 - Archived data from Mon, 07. August 2017 16:42:40 CEST
					This is all the information about APD 0711006311. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 0711006311 | 
| Type: | Hamamatsu Avalanche Photo Diode | 
| Detector: | unassigned | 
| Unit: | unassigned | 
| Preamp: | 0 | 
| Current location: | unknown | 
| Installation information: | |
| Label: | none | 
| Manufacturer information: | |
| Wafer position: | E03 | 
| Break-through voltage: | 415 V | 
| Voltage for Gain 100 (T=+25°C): | 386.6 V | 
| Dark current: | 11.5 nA | 
| Screening Logistics: | |
| Available: | Yes | 
| Storage Box: | 299 | 
| Position in Box: | 8 | 
| EP1 batch: | none | 
| EP1 batch after irradiation: | none | 
| Shipment: | |
| Grid number: | 46 | 
| Position in grid: | 11 | 
| Arrival for irradiation: | 31. Jul 2017 | 
| Sent for analysis after irradiation: | none | 
| Return for assembly: | none | 
| Irradiation: | |
| Date: | none | 
| Dose used: | none | 
| Temperature: | none | 
| Position: | none | 
| Bias voltage: | none | 
| Annealing: | |
| Date: | none | 
| Temperature: | none | 
| Duration: | none | 
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none | 
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none | 
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none | 
| Break-through voltage: | T = +20 °C: none T = -25 °C: none | 
| Notes: | 
						
					
Version history
| Time | Author | Change comment | 
|---|---|---|
| 05. Feb 2021 11:26:51 CET | jreher | Updated box and position via API. | 
| 11. Aug 2020 17:56:57 CEST | jreher | Updated APD characteristics via API. | 
| 21. Jul 2020 14:42:39 CEST | jreher | Updated APD location via API. | 
| 21. Jul 2020 14:42:30 CEST | jreher | Updated box and position via API. | 
| 19. Dec 2019 15:50:07 CET | spankonin | Updated APD batch assignment via API. | 
| 19. Dec 2019 15:17:42 CET | jreher | Updated box and position via API. | 
| 23. Aug 2017 15:54:04 CEST | markus.moritz | Entered shipped after irradiation date. | 
| 11. Aug 2017 14:10:09 CEST | hans-georg.zaunick | Entered irradiation information. | 
| 11. Aug 2017 12:58:49 CEST | hans-georg.zaunick | Entered irradiation information. | 
| 07. Aug 2017 16:52:30 CEST | hans-georg.zaunick | Entered arrival for irradiation date. | 
| 07. Aug 2017 16:42:40 CEST | hans-georg.zaunick | Entered arrival for irradiation date. | 
| 04. Aug 2017 03:14:57 CEST | Tobias | Assigned to grid via information extracted from APD DB. | 
| 22. Jun 2016 15:13:08 CEST | Tobias | Imported from Hamamatsu datasheet. | 
 
						 
					