RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1603016935 - Archived data from Tue, 08. September 2020 17:13:47 CEST


This is all the information about APD 1603016935. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1603016935
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B06
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 388.3 V
Dark current: 5.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 361
Position in Box: 48
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 388.3788045 V     T = -25 °C: 352.4030814 V
Voltage for Gain 150: T = +20 °C: 396.306971 V     T = -25 °C: 359.014042 V
Voltage for Gain 200: T = +20 °C: 400.6991664 V     T = -25 °C: 363.6226082 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.442953398 V-1     T = -25 °C: 17.79303688 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.654730945 V-1     T = -25 °C: 10.02095254 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.04101888 V-1     T = -25 °C: 8.19616141 V-1
Break-through voltage: T = +20 °C: 412.8001326 V     T = -25 °C: 379.0272911 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:34:39 CET jreher Updated box and position via API.
05. Feb 2021 11:29:55 CET jreher Updated box and position via API.
08. Sep 2020 17:13:47 CEST vwerner Updated APD batch assignment via API.
11. Aug 2020 18:10:31 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:53:19 CEST jreher Updated APD location via API.
21. Jul 2020 16:15:59 CEST jreher Updated APD batch assignment via API.
09. Nov 2017 16:48:29 CET Tobias Removed APD from grid as the grid arrived in Gießen without it.
09. Nov 2017 15:11:38 CET markus.moritz Entered arrival for irradiation date.
02. Nov 2017 15:16:55 CET Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:42:21 CEST Tobias Imported from Hamamatsu datasheet.