Show Hamamatsu Avalanche Photo Diode 0711006264 - Archived data from Wed, 07. October 2020 15:44:59 CEST
This is all the information about APD 0711006264. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 0711006264 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | In transit to Mainz |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | G12 |
| Break-through voltage: | 421 V |
| Voltage for Gain 100 (T=+25°C): | 393.7 V |
| Dark current: | 11.4 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 292 |
| Position in Box: | 38 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 44 |
| Position in grid: | 7 |
| Arrival for irradiation: | 20. Jun 2016 |
| Sent for analysis after irradiation: | 08. Jul 2016 |
| Return for assembly: | 04. Aug 2016 |
| Irradiation: | |
| Date: | 30. Jun 2016 |
| Dose used: | 30 Gy |
| Temperature: | 25 °C |
| Position: | 1 |
| Bias voltage: | 320 V (connection unknown) |
| Annealing: | |
| Date: | 01. Jul 2016 |
| Temperature: | 80 °C |
| Duration: | 8 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 393.6964806 V T = -25 °C: 357.3908138 V |
| Voltage for Gain 150: | T = +20 °C: 401.5652878 V T = -25 °C: 365.0108626 V |
| Voltage for Gain 200: | T = +20 °C: 405.9061156 V T = -25 °C: 369.2867544 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.374806165 V-1 T = -25 °C: 4.626721175 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.508369644 V-1 T = -25 °C: 9.219988608 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 14.84486661 V-1 T = -25 °C: 14.3603639 V-1 |
| Break-through voltage: | T = +20 °C: 419.6026007 V T = -25 °C: 384.002537 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 11:26:00 CET | jreher | Updated box and position via API. |
| 07. Oct 2020 15:44:59 CEST | jreher | Updated APD location via API. |
| 11. Aug 2020 17:40:44 CEST | jreher | Updated APD characteristics via API. |
| 21. Jul 2020 14:41:03 CEST | jreher | Updated box and position via API. |
| 27. Nov 2019 20:19:13 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:31:39 CET | jreher | Updated box and position via API. |
| 22. Oct 2019 14:33:21 CEST | spankonin | Updated APD location via API. |
| 15. Oct 2019 11:00:19 CEST | jgrochowski | Updated APD batch assignment via API. |
| 19. Jan 2017 11:06:03 CET | tobias | Added irradiation/annealing data after fixing PSL S/N issue. |
| 18. Jan 2017 16:29:29 CET | Tobias | Assigned to grid via information extracted from APD DB. |
| 22. Jun 2016 15:13:07 CEST | Tobias | Imported from Hamamatsu datasheet. |