Show Hamamatsu Avalanche Photo Diode 1601016798 - Archived data from Mon, 01. August 2016 17:29:53 CEST
This is all the information about APD 1601016798. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1601016798 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | unknown |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | F03 |
| Break-through voltage: | 411 V |
| Voltage for Gain 100 (T=+25°C): | 382.7 V |
| Dark current: | 5.7 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 40 |
| Position in Box: | 31 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 428 |
| Position in grid: | 19 |
| Arrival for irradiation: | none |
| Sent for analysis after irradiation: | none |
| Return for assembly: | none |
| Irradiation: | |
| Date: | none |
| Dose used: | none |
| Temperature: | none |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
| Break-through voltage: | T = +20 °C: none T = -25 °C: none |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 10:53:23 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:19:09 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:26:14 CEST | jreher | Updated APD characteristics via API. |
| 27. Mar 2020 11:32:36 CET | jreher | Assigned to capsule by script |
| 13. Feb 2020 15:25:39 CET | jreher | Updated box and position via API. |
| 27. Nov 2019 19:36:05 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:14:04 CET | jreher | Updated box and position via API. |
| 04. Jul 2019 11:11:03 CEST | jreher | Updated APD location via API. |
| 12. Jun 2019 16:48:24 CEST | jreher | Updated APD batch assignment via API. |
| 12. Jun 2019 16:33:20 CEST | jreher | Updated APD batch assignment via API. |
| 26. Nov 2018 14:59:36 CET | markus.moritz | |
| 29. Sep 2017 13:46:17 CEST | markus.moritz | Entered arrival for irradiation date. |
| 01. Aug 2016 17:29:53 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 23. Jun 2016 10:42:19 CEST | Tobias | Imported from Hamamatsu datasheet. |