Subdetector specification:  
Serial: 1601016796
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G08
Break-through voltage: 418 V
Voltage for Gain 100 (T=+25°C): 390.1 V
Dark current: 6.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 40
Position in Box: 29
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 428
Position in grid: 17
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 26. Nov 2018
Return for assembly: none
   
Irradiation:  
Date: 22. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 23. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 390.6358488 V     T = -25 °C: 354.6239776 V
Voltage for Gain 150: T = +20 °C: 398.5919531 V     T = -25 °C: 362.2936396 V
Voltage for Gain 200: T = +20 °C: 402.9725652 V     T = -25 °C: 366.5852552 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.334907771 V-1     T = -25 °C: 4.370299635 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.672826805 V-1     T = -25 °C: 8.373656953 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.09301118 V-1     T = -25 °C: 15.4941588 V-1
Break-through voltage: T = +20 °C: 418.560682 V     T = -25 °C: 382.4594762 V
   
Notes:


Version history

Time Author Change comment
15. Nov 2022 13:15:16 CET oafedulidis Assigned to capsule by script
16. Dec 2021 13:42:18 CET oafedulidis Updated box and position via API.
05. Feb 2021 10:53:23 CET jreher Updated box and position via API.
03. Feb 2021 18:19:09 CET jreher Updated box and position via API.
11. Aug 2020 17:26:14 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:36:05 CET jreher Updated APD location via API.
25. Nov 2019 17:14:04 CET jreher Updated box and position via API.
04. Jul 2019 11:11:03 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:24 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:20 CEST jreher Updated APD batch assignment via API.
26. Nov 2018 15:00:48 CET markus.moritz
29. Sep 2017 13:46:17 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:52 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:42:19 CEST Tobias Imported from Hamamatsu datasheet.