Show Hamamatsu Avalanche Photo Diode 1503016698 - Archived data from Tue, 11. August 2020 17:26:06 CEST
This is all the information about APD 1503016698. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1503016698 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | H06 |
| Break-through voltage: | 411 V |
| Voltage for Gain 100 (T=+25°C): | 385.8 V |
| Dark current: | 4.2 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 39 |
| Position in Box: | 39 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 424 |
| Position in grid: | 11 |
| Arrival for irradiation: | 29. Sep 2017 |
| Sent for analysis after irradiation: | 16. Jan 2019 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 28. Nov 2018 |
| Dose used: | 37 Gy |
| Temperature: | 20 °C |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | 30. Nov 2018 |
| Temperature: | 80 °C |
| Duration: | 48 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 388.0752908 V T = -25 °C: 351.8465777 V |
| Voltage for Gain 150: | T = +20 °C: 396.0310492 V T = -25 °C: 359.4658273 V |
| Voltage for Gain 200: | T = +20 °C: 400.4507439 V T = -25 °C: 363.7615165 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.376786576 V-1 T = -25 °C: 4.677935733 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 9.130910134 V-1 T = -25 °C: 9.062617765 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 13.8295117 V-1 T = -25 °C: 15.29577037 V-1 |
| Break-through voltage: | T = +20 °C: 410.0154039 V T = -25 °C: 377.031483 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 10:53:16 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:19:02 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:26:06 CEST | jreher | Updated APD characteristics via API. |
| 27. Nov 2019 19:35:55 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:14:00 CET | jreher | Updated box and position via API. |
| 04. Jul 2019 11:10:56 CEST | jreher | Updated APD location via API. |
| 12. Jun 2019 16:48:20 CEST | jreher | Updated APD batch assignment via API. |
| 12. Jun 2019 16:33:16 CEST | jreher | Updated APD batch assignment via API. |
| 18. Jan 2019 14:35:43 CET | markus.moritz | |
| 03. Dec 2018 11:38:22 CET | markus.moritz | |
| 29. Sep 2017 11:55:32 CEST | markus.moritz | Entered arrival for irradiation date. |
| 01. Aug 2016 17:29:49 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 23. Jun 2016 10:42:16 CEST | Tobias | Imported from Hamamatsu datasheet. |