Show Hamamatsu Avalanche Photo Diode 0710006251 - Archived data from Wed, 03. August 2016 15:57:46 CEST
This is all the information about APD 0710006251. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 0710006251 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | unknown |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | F10 |
| Break-through voltage: | 413 V |
| Voltage for Gain 100 (T=+25°C): | 384.2 V |
| Dark current: | 16.3 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 292 |
| Position in Box: | 36 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 44 |
| Position in grid: | 6 |
| Arrival for irradiation: | 20. Jun 2016 |
| Sent for analysis after irradiation: | none |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 30. Jun 2016 |
| Dose used: | 30 Gy |
| Temperature: | 25 °C |
| Position: | 1 |
| Bias voltage: | 320 V (connection unknown) |
| Annealing: | |
| Date: | 01. Jul 2016 |
| Temperature: | 80 °C |
| Duration: | 8 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
| Break-through voltage: | T = +20 °C: none T = -25 °C: none |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 17. Apr 2021 01:10:34 CEST | jreher | Updated APD location via API. |
| 05. Feb 2021 11:26:00 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:40:44 CEST | jreher | Updated APD characteristics via API. |
| 21. Jul 2020 14:41:03 CEST | jreher | Updated box and position via API. |
| 03. Apr 2020 09:45:22 CEST | jreher | Assigned to capsule by script |
| 13. Feb 2020 14:23:21 CET | jreher | Updated box and position via API. |
| 27. Nov 2019 20:19:13 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:31:38 CET | jreher | Updated box and position via API. |
| 22. Oct 2019 14:33:21 CEST | spankonin | Updated APD location via API. |
| 15. Oct 2019 11:00:19 CEST | jgrochowski | Updated APD batch assignment via API. |
| 04. Aug 2016 13:23:04 CEST | markus.moritz | Entered return for assembly date. |
| 03. Aug 2016 15:58:02 CEST | markus.moritz | Entered shipped after irradiation date. |
| 03. Aug 2016 15:57:46 CEST | markus.moritz | Entered arrival for irradiation date. |
| 02. Aug 2016 14:53:28 CEST | christopher.l.hahn | Entered annealing information. |
| 02. Aug 2016 13:55:50 CEST | markus.moritz | Entered irradiation information. |
| 01. Aug 2016 17:27:46 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 22. Jun 2016 15:13:07 CEST | Tobias | Imported from Hamamatsu datasheet. |