Show Hamamatsu Avalanche Photo Diode 1503016676 - Archived data from Tue, 11. August 2020 17:26:03 CEST
This is all the information about APD 1503016676. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1503016676 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | D15 |
| Break-through voltage: | 415 V |
| Voltage for Gain 100 (T=+25°C): | 389.7 V |
| Dark current: | 7.6 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 39 |
| Position in Box: | 23 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 430 |
| Position in grid: | 5 |
| Arrival for irradiation: | 29. Sep 2017 |
| Sent for analysis after irradiation: | 16. Jan 2019 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | none |
| Dose used: | none |
| Temperature: | none |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 389.5192516 V T = -25 °C: 353.1285088 V |
| Voltage for Gain 150: | T = +20 °C: 397.4096571 V T = -25 °C: 360.7182309 V |
| Voltage for Gain 200: | T = +20 °C: 401.7824651 V T = -25 °C: 364.9680213 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.585901191 V-1 T = -25 °C: 4.588311857 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.915055994 V-1 T = -25 °C: 8.94750682 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 15.28949319 V-1 T = -25 °C: 15.24565971 V-1 |
| Break-through voltage: | T = +20 °C: 414.5981405 V T = -25 °C: 378.3495365 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 10:53:14 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:19:00 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:26:03 CEST | jreher | Updated APD characteristics via API. |
| 27. Nov 2019 19:35:53 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:13:59 CET | jreher | Updated box and position via API. |
| 04. Jul 2019 11:10:54 CEST | jreher | Updated APD location via API. |
| 12. Jun 2019 16:48:19 CEST | jreher | Updated APD batch assignment via API. |
| 12. Jun 2019 16:33:15 CEST | jreher | Updated APD batch assignment via API. |
| 18. Jan 2019 14:41:31 CET | markus.moritz | |
| 29. Sep 2017 12:32:45 CEST | markus.moritz | Entered arrival for irradiation date. |
| 01. Aug 2016 17:29:53 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 23. Jun 2016 10:42:16 CEST | Tobias | Imported from Hamamatsu datasheet. |