Show Hamamatsu Avalanche Photo Diode 1502016578 - Archived data from Mon, 01. August 2016 17:29:48 CEST
					This is all the information about APD 1502016578. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1502016578 | 
| Type: | Hamamatsu Avalanche Photo Diode | 
| Detector: | unassigned | 
| Unit: | unassigned | 
| Preamp: | 0 | 
| Current location: | unknown | 
| Installation information: | |
| Label: | none | 
| Manufacturer information: | |
| Wafer position: | D07 | 
| Break-through voltage: | 414 V | 
| Voltage for Gain 100 (T=+25°C): | 385.1 V | 
| Dark current: | 5.3 nA | 
| Screening Logistics: | |
| Available: | Yes | 
| Storage Box: | 31 | 
| Position in Box: | 9 | 
| EP1 batch: | none | 
| EP1 batch after irradiation: | none | 
| Shipment: | |
| Grid number: | 421 | 
| Position in grid: | 1 | 
| Arrival for irradiation: | none | 
| Sent for analysis after irradiation: | none | 
| Return for assembly: | none | 
| Irradiation: | |
| Date: | none | 
| Dose used: | none | 
| Temperature: | none | 
| Position: | none | 
| Bias voltage: | none | 
| Annealing: | |
| Date: | none | 
| Temperature: | none | 
| Duration: | none | 
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none | 
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none | 
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none | 
| Break-through voltage: | T = +20 °C: none T = -25 °C: none | 
| Notes: | 
						
					
Version history
| Time | Author | Change comment | 
|---|---|---|
| 05. Feb 2021 10:51:50 CET | jreher | Updated box and position via API. | 
| 03. Feb 2021 18:17:55 CET | jreher | Updated box and position via API. | 
| 11. Aug 2020 17:24:40 CEST | jreher | Updated APD characteristics via API. | 
| 28. Nov 2019 12:22:02 CET | jreher | Updated APD location via API. | 
| 25. Nov 2019 17:13:18 CET | jreher | Updated box and position via API. | 
| 13. Jun 2019 11:28:32 CEST | jreher | Updated APD location via API. | 
| 12. Jun 2019 16:47:42 CEST | jreher | Updated APD batch assignment via API. | 
| 12. Jun 2019 16:32:37 CEST | jreher | Updated APD batch assignment via API. | 
| 26. Nov 2018 15:27:01 CET | markus.moritz | |
| 29. Sep 2017 13:48:04 CEST | markus.moritz | Entered arrival for irradiation date. | 
| 01. Aug 2016 17:29:48 CEST | Tobias | Assigned to grid via information extracted from APD DB. | 
| 23. Jun 2016 10:41:03 CEST | Tobias | Imported from Hamamatsu datasheet. | 
 
						 
					