Show Hamamatsu Avalanche Photo Diode 1502016565 - Archived data from Tue, 11. August 2020 17:24:38 CEST
					This is all the information about APD 1502016565. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1502016565 | 
| Type: | Hamamatsu Avalanche Photo Diode | 
| Detector: | unassigned | 
| Unit: | unassigned | 
| Preamp: | 0 | 
| Current location: | Bochum | 
| Installation information: | |
| Label: | none | 
| Manufacturer information: | |
| Wafer position: | D08 | 
| Break-through voltage: | 415 V | 
| Voltage for Gain 100 (T=+25°C): | 385.9 V | 
| Dark current: | 4.8 nA | 
| Screening Logistics: | |
| Available: | Yes | 
| Storage Box: | 30 | 
| Position in Box: | 44 | 
| EP1 batch: | none | 
| EP1 batch after irradiation: | none | 
| Shipment: | |
| Grid number: | 420 | 
| Position in grid: | 10 | 
| Arrival for irradiation: | 29. Sep 2017 | 
| Sent for analysis after irradiation: | 03. Jan 2019 | 
| Return for assembly: | none | 
| Irradiation: | |
| Date: | 05. Dec 2018 | 
| Dose used: | 37 Gy | 
| Temperature: | 20 °C | 
| Position: | none | 
| Bias voltage: | none | 
| Annealing: | |
| Date: | 10. Dec 2018 | 
| Temperature: | 80 °C | 
| Duration: | 48 h | 
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 386.545371 V T = -25 °C: 350.318134 V | 
| Voltage for Gain 150: | T = +20 °C: 394.5315192 V T = -25 °C: 357.9036386 V | 
| Voltage for Gain 200: | T = +20 °C: 398.9716505 V T = -25 °C: 362.163089 V | 
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.539231872 V-1 T = -25 °C: 4.897234086 V-1 | 
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.681281627 V-1 T = -25 °C: 8.739627806 V-1 | 
| Gain/Voltage slope at M = 200: | T = +20 °C: 14.60021146 V-1 T = -25 °C: 14.75067712 V-1 | 
| Break-through voltage: | T = +20 °C: 414.6099019 V T = -25 °C: 377.8833875 V | 
| Notes: | 
						
					
Version history
| Time | Author | Change comment | 
|---|---|---|
| 05. Feb 2021 10:51:45 CET | jreher | Updated box and position via API. | 
| 03. Feb 2021 18:17:51 CET | jreher | Updated box and position via API. | 
| 11. Aug 2020 17:24:38 CEST | jreher | Updated APD characteristics via API. | 
| 28. Nov 2019 12:21:53 CET | jreher | Updated APD location via API. | 
| 25. Nov 2019 17:13:16 CET | jreher | Updated box and position via API. | 
| 13. Jun 2019 11:19:40 CEST | jreher | Updated APD location via API. | 
| 13. Jun 2019 11:19:03 CEST | jreher | Updated APD location via API. | 
| 12. Jun 2019 16:47:40 CEST | jreher | Updated APD batch assignment via API. | 
| 12. Jun 2019 16:32:35 CEST | jreher | Updated APD batch assignment via API. | 
| 03. Jan 2019 14:17:06 CET | markus.moritz | |
| 29. Sep 2017 14:10:01 CEST | markus.moritz | Entered arrival for irradiation date. | 
| 01. Aug 2016 17:29:44 CEST | Tobias | Assigned to grid via information extracted from APD DB. | 
| 23. Jun 2016 10:41:03 CEST | Tobias | Imported from Hamamatsu datasheet. |