Show Hamamatsu Avalanche Photo Diode 1501016503 - Archived data from Wed, 03. February 2021 18:18:19 CET
This is all the information about APD 1501016503. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1501016503 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | D07 |
| Break-through voltage: | 420 V |
| Voltage for Gain 100 (T=+25°C): | 390.7 V |
| Dark current: | 3.9 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 34 |
| Position in Box: | 8 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 417 |
| Position in grid: | 17 |
| Arrival for irradiation: | 29. Sep 2017 |
| Sent for analysis after irradiation: | 26. Nov 2018 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 22. Nov 2018 |
| Dose used: | 37 Gy |
| Temperature: | 20 °C |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | 23. Nov 2018 |
| Temperature: | 80 °C |
| Duration: | 48 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 391.3066534 V T = -25 °C: 354.5059416 V |
| Voltage for Gain 150: | T = +20 °C: 399.2623665 V T = -25 °C: 362.1216061 V |
| Voltage for Gain 200: | T = +20 °C: 403.6904257 V T = -25 °C: 366.4241299 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.47147451 V-1 T = -25 °C: 4.466118733 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.747997335 V-1 T = -25 °C: 8.873876796 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 14.3750913 V-1 T = -25 °C: 15.34793147 V-1 |
| Break-through voltage: | T = +20 °C: 419.6687288 V T = -25 °C: 382.4755975 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 15. Nov 2022 13:06:03 CET | oafedulidis | Assigned to capsule by script |
| 30. Aug 2021 14:07:24 CEST | oafedulidis | Updated box and position via API. |
| 05. Feb 2021 10:52:13 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:18:19 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:25:10 CEST | jreher | Updated APD characteristics via API. |
| 28. Nov 2019 12:22:36 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:13:32 CET | jreher | Updated box and position via API. |
| 13. Jun 2019 11:29:14 CEST | jreher | Updated APD location via API. |
| 12. Jun 2019 16:47:55 CEST | jreher | Updated APD batch assignment via API. |
| 12. Jun 2019 16:32:50 CEST | jreher | Updated APD batch assignment via API. |
| 26. Nov 2018 14:59:25 CET | markus.moritz | |
| 29. Sep 2017 13:46:42 CEST | markus.moritz | Entered arrival for irradiation date. |
| 01. Aug 2016 17:29:42 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 23. Jun 2016 10:41:01 CEST | Tobias | Imported from Hamamatsu datasheet. |