Show Hamamatsu Avalanche Photo Diode 1417016459 - Archived data from Wed, 03. February 2021 18:19:00 CET
This is all the information about APD 1417016459. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1417016459 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | F04 |
| Break-through voltage: | 419 V |
| Voltage for Gain 100 (T=+25°C): | 392.1 V |
| Dark current: | 6.7 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 39 |
| Position in Box: | 18 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 416 |
| Position in grid: | 3 |
| Arrival for irradiation: | 29. Sep 2017 |
| Sent for analysis after irradiation: | 03. Jan 2019 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 29. Nov 2018 |
| Dose used: | 37 Gy |
| Temperature: | 20 °C |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | 30. Nov 2018 |
| Temperature: | 80 °C |
| Duration: | 48 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 393.2266539 V T = -25 °C: 356.8629977 V |
| Voltage for Gain 150: | T = +20 °C: 401.116662 V T = -25 °C: 364.6054049 V |
| Voltage for Gain 200: | T = +20 °C: 405.5025081 V T = -25 °C: 368.7922788 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.038351989 V-1 T = -25 °C: 5.010646315 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 9.23063888 V-1 T = -25 °C: 9.976907575 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 14.33422277 V-1 T = -25 °C: 16.67646235 V-1 |
| Break-through voltage: | T = +20 °C: 420.3314377 V T = -25 °C: 383.8724237 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 15. Nov 2022 12:52:48 CET | oafedulidis | Assigned to capsule by script |
| 09. Dec 2021 13:11:01 CET | oafedulidis | Updated box and position via API. |
| 05. Feb 2021 10:53:14 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:19:00 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:26:01 CEST | jreher | Updated APD characteristics via API. |
| 27. Nov 2019 19:35:53 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:13:58 CET | jreher | Updated box and position via API. |
| 04. Jul 2019 11:10:54 CEST | jreher | Updated APD location via API. |
| 12. Jun 2019 16:48:18 CEST | jreher | Updated APD batch assignment via API. |
| 12. Jun 2019 16:33:14 CEST | jreher | Updated APD batch assignment via API. |
| 03. Jan 2019 14:36:16 CET | markus.moritz | Entered shipped after irradiation date. |
| 03. Dec 2018 14:39:00 CET | markus.moritz | |
| 29. Sep 2017 12:30:55 CEST | markus.moritz | Entered arrival for irradiation date. |
| 01. Aug 2016 17:29:41 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 23. Jun 2016 10:41:00 CEST | Tobias | Imported from Hamamatsu datasheet. |