RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1417016453 - Archived data from Tue, 11. August 2020 17:26:01 CEST


This is all the information about APD 1417016453. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1417016453
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D03
Break-through voltage: 425 V
Voltage for Gain 100 (T=+25°C): 396 V
Dark current: 7.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 39
Position in Box: 16
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 416
Position in grid: 1
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 03. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 29. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 30. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 396.4023756 V     T = -25 °C: 359.6643708 V
Voltage for Gain 150: T = +20 °C: 404.3309097 V     T = -25 °C: 367.357423 V
Voltage for Gain 200: T = +20 °C: 408.7707754 V     T = -25 °C: 371.7529116 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.151692154 V-1     T = -25 °C: 4.561683363 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.843417549 V-1     T = -25 °C: 8.565490616 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.91083502 V-1     T = -25 °C: 13.90049275 V-1
Break-through voltage: T = +20 °C: 424.6425214 V     T = -25 °C: 387.882968 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:53:14 CET jreher Updated box and position via API.
03. Feb 2021 18:19:00 CET jreher Updated box and position via API.
11. Aug 2020 17:26:01 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:35:53 CET jreher Updated APD location via API.
25. Nov 2019 17:13:58 CET jreher Updated box and position via API.
04. Jul 2019 11:10:54 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:18 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:14 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 14:36:16 CET markus.moritz Entered shipped after irradiation date.
03. Dec 2018 14:39:46 CET markus.moritz
29. Sep 2017 12:30:55 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:41 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:41:00 CEST Tobias Imported from Hamamatsu datasheet.