Show Hamamatsu Avalanche Photo Diode 1417016438 - Archived data from Wed, 07. October 2020 15:45:02 CEST
This is all the information about APD 1417016438. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1417016438 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | In transit to Mainz |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | E08 |
| Break-through voltage: | 419 V |
| Voltage for Gain 100 (T=+25°C): | 390.5 V |
| Dark current: | 6 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 303 |
| Position in Box: | 22 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 415 |
| Position in grid: | 8 |
| Arrival for irradiation: | 29. Sep 2017 |
| Sent for analysis after irradiation: | 03. Nov 2017 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 26. Oct 2017 |
| Dose used: | 45 Gy |
| Temperature: | 20 °C |
| Position: | 4 |
| Bias voltage: | 390.5 V (connected) |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 390.5669938 V T = -25 °C: 354.4202789 V |
| Voltage for Gain 150: | T = +20 °C: 398.5114563 V T = -25 °C: 361.9536118 V |
| Voltage for Gain 200: | T = +20 °C: 402.9100467 V T = -25 °C: 366.1866257 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.360212883 V-1 T = -25 °C: 4.657566154 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.431512895 V-1 T = -25 °C: 9.331799459 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 14.588153 V-1 T = -25 °C: 14.62405449 V-1 |
| Break-through voltage: | T = +20 °C: 418.8737949 V T = -25 °C: 382.0848921 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 11:27:24 CET | jreher | Updated box and position via API. |
| 07. Oct 2020 15:45:02 CEST | jreher | Updated APD location via API. |
| 11. Aug 2020 17:57:40 CEST | jreher | Updated APD characteristics via API. |
| 21. Jul 2020 14:43:41 CEST | jreher | Updated APD location via API. |
| 21. Jul 2020 14:43:31 CEST | jreher | Updated box and position via API. |
| 19. Dec 2019 16:19:20 CET | spankonin | Updated APD batch assignment via API. |
| 19. Dec 2019 15:18:14 CET | jreher | Updated box and position via API. |
| 03. Nov 2017 16:13:19 CET | markus.moritz | Entered shipped after irradiation date. |
| 26. Oct 2017 16:36:48 CEST | markus.moritz | Entered irradiation information. |
| 29. Sep 2017 12:19:35 CEST | markus.moritz | Entered arrival for irradiation date. |
| 01. Aug 2016 17:29:40 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 23. Jun 2016 10:41:00 CEST | Tobias | Imported from Hamamatsu datasheet. |