Subdetector specification:  
Serial: 1417016415
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F11
Break-through voltage: 424 V
Voltage for Gain 100 (T=+25°C): 395.8 V
Dark current: 9.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 39
Position in Box: 4
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 414
Position in grid: 6
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 16. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 30. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 395.7492004 V     T = -25 °C: 359.1924054 V
Voltage for Gain 150: T = +20 °C: 403.6466695 V     T = -25 °C: 366.8954141 V
Voltage for Gain 200: T = +20 °C: 408.0353975 V     T = -25 °C: 371.2284969 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.57306246 V-1     T = -25 °C: 4.686673638 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.514421594 V-1     T = -25 °C: 9.234432684 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.18913165 V-1     T = -25 °C: 14.7664973 V-1
Break-through voltage: T = +20 °C: 423.5200381 V     T = -25 °C: 386.9489284 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:53:12 CET jreher Updated box and position via API.
03. Feb 2021 18:18:58 CET jreher Updated box and position via API.
11. Aug 2020 17:25:59 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:35:52 CET jreher Updated APD location via API.
25. Nov 2019 17:13:57 CET jreher Updated box and position via API.
04. Jul 2019 11:10:53 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:17 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:13 CEST jreher Updated APD batch assignment via API.
18. Jan 2019 14:33:23 CET markus.moritz Entered shipped after irradiation date.
03. Dec 2018 10:37:59 CET markus.moritz
29. Sep 2017 09:49:04 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:40 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:40:59 CEST Tobias Imported from Hamamatsu datasheet.