Show Hamamatsu Avalanche Photo Diode 1416016307 - Archived data from Wed, 07. October 2020 15:44:49 CEST
This is all the information about APD 1416016307. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1416016307 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | In transit to Mainz |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | E02 |
| Break-through voltage: | 420 V |
| Voltage for Gain 100 (T=+25°C): | 391.3 V |
| Dark current: | 6.7 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 289 |
| Position in Box: | 33 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 409 |
| Position in grid: | 16 |
| Arrival for irradiation: | 29. Sep 2017 |
| Sent for analysis after irradiation: | none |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 22. Feb 2018 |
| Dose used: | 30 Gy |
| Temperature: | 25 °C |
| Position: | 2 |
| Bias voltage: | 0 V (connected) |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 392.2949252 V T = -25 °C: 355.9653106 V |
| Voltage for Gain 150: | T = +20 °C: 400.3200267 V T = -25 °C: 363.6171208 V |
| Voltage for Gain 200: | T = +20 °C: 404.768584 V T = -25 °C: 367.9183457 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.375670354 V-1 T = -25 °C: 4.740408042 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.465691876 V-1 T = -25 °C: 9.393414474 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 14.41639078 V-1 T = -25 °C: 14.61471219 V-1 |
| Break-through voltage: | T = +20 °C: 419.473635 V T = -25 °C: 383.1530425 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 11:25:36 CET | jreher | Updated box and position via API. |
| 07. Oct 2020 15:44:49 CEST | jreher | Updated APD location via API. |
| 11. Aug 2020 17:40:14 CEST | jreher | Updated APD characteristics via API. |
| 21. Jul 2020 14:40:32 CEST | jreher | Updated box and position via API. |
| 27. Nov 2019 20:18:39 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:31:24 CET | jreher | Updated box and position via API. |
| 22. Oct 2019 14:31:15 CEST | spankonin | Updated APD location via API. |
| 14. Oct 2019 17:33:22 CEST | jgrochowski | Updated APD batch assignment via API. |
| 05. Apr 2018 12:28:22 CEST | markus.moritz | Entered irradiation information. |
| 29. Sep 2017 14:09:35 CEST | markus.moritz | Entered arrival for irradiation date. |
| 01. Aug 2016 17:29:37 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 23. Jun 2016 10:40:56 CEST | Tobias | Imported from Hamamatsu datasheet. |