Subdetector specification:  
Serial: 0710006209
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 0710006209/2303024378
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: H10
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 385.6 V
Dark current: 17.9 nA
   
Screening Logistics:  
Available: No
Storage Box: 211
Position in Box: 12
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.7838877 V     T = -25 °C: 349.8216334 V
Voltage for Gain 150: T = +20 °C: 393.6277856 V     T = -25 °C: 357.2614059 V
Voltage for Gain 200: T = +20 °C: 397.9614089 V     T = -25 °C: 361.4652345 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.691607693 V-1     T = -25 °C: 4.957347941 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.401151369 V-1     T = -25 °C: 9.166415542 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.75297902 V-1     T = -25 °C: 14.39394802 V-1
Break-through voltage: T = +20 °C: 411.3324047 V     T = -25 °C: 375.5549843 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:15:29 CET jreher Updated box and position via API.
25. Jan 2021 14:45:05 CET jreher Assigned to capsule by script
17. Aug 2020 15:51:00 CEST jreher Updated box and position via API.
11. Aug 2020 17:43:55 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:26:05 CEST jreher Updated box and position via API.
20. Feb 2020 13:35:22 CET jreher Updated box and position via API.
28. Nov 2019 12:50:41 CET spankonin Updated box and position via API.
27. Nov 2019 20:06:16 CET jreher Updated APD location via API.
25. Nov 2019 17:27:17 CET jreher Updated box and position via API.
31. Oct 2019 17:09:41 CET spankonin Updated APD batch assignment via API.
31. Oct 2019 16:57:50 CET spankonin Updated APD location via API.
22. Jun 2016 15:13:06 CEST Tobias Imported from Hamamatsu datasheet.