Show Hamamatsu Avalanche Photo Diode 1414016133 - Archived data from Thu, 19. December 2019 16:48:01 CET
This is all the information about APD 1414016133. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1414016133 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | unknown |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | E06 |
| Break-through voltage: | 418 V |
| Voltage for Gain 100 (T=+25°C): | 389.2 V |
| Dark current: | 4.9 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 309 |
| Position in Box: | 35 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 403 |
| Position in grid: | 10 |
| Arrival for irradiation: | 29. Sep 2017 |
| Sent for analysis after irradiation: | 20. Oct 2017 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 20. Oct 2017 |
| Dose used: | 45 Gy |
| Temperature: | 20 °C |
| Position: | 3 |
| Bias voltage: | 389.2 V (connected) |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
| Break-through voltage: | T = +20 °C: none T = -25 °C: none |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 16. Nov 2022 10:00:10 CET | oafedulidis | Assigned to capsule by script |
| 05. Feb 2021 11:28:21 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:58:43 CEST | jreher | Updated APD characteristics via API. |
| 21. Jul 2020 14:45:11 CEST | jreher | Updated APD location via API. |
| 21. Jul 2020 14:45:01 CEST | jreher | Updated box and position via API. |
| 19. Dec 2019 16:48:01 CET | spankonin | Updated APD batch assignment via API. |
| 19. Dec 2019 15:19:02 CET | jreher | Updated box and position via API. |
| 20. Oct 2017 14:31:54 CEST | markus.moritz | Entered shipped after irradiation date. |
| 20. Oct 2017 09:51:22 CEST | markus.moritz | Entered irradiation information. |
| 29. Sep 2017 11:33:00 CEST | markus.moritz | Entered arrival for irradiation date. |
| 01. Aug 2016 17:29:33 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 23. Jun 2016 10:39:49 CEST | Tobias | Imported from Hamamatsu datasheet. |