Show Hamamatsu Avalanche Photo Diode 1414016130 - Archived data from Tue, 11. August 2020 17:58:43 CEST
This is all the information about APD 1414016130. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1414016130 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | F05 |
| Break-through voltage: | 419 V |
| Voltage for Gain 100 (T=+25°C): | 390.3 V |
| Dark current: | 4.7 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 309 |
| Position in Box: | 32 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 403 |
| Position in grid: | 7 |
| Arrival for irradiation: | 29. Sep 2017 |
| Sent for analysis after irradiation: | 20. Oct 2017 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 20. Oct 2017 |
| Dose used: | 45 Gy |
| Temperature: | 20 °C |
| Position: | 3 |
| Bias voltage: | 390.3 V (connected) |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 390.781683 V T = -25 °C: 354.6009391 V |
| Voltage for Gain 150: | T = +20 °C: 398.666031 V T = -25 °C: 362.1454427 V |
| Voltage for Gain 200: | T = +20 °C: 403.0345489 V T = -25 °C: 366.3935071 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.66178948 V-1 T = -25 °C: 4.630756953 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 9.279862377 V-1 T = -25 °C: 9.16083932 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 14.50903403 V-1 T = -25 °C: 14.26969911 V-1 |
| Break-through voltage: | T = +20 °C: 418.6250027 V T = -25 °C: 382.1598206 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 11:28:20 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:58:43 CEST | jreher | Updated APD characteristics via API. |
| 21. Jul 2020 14:45:10 CEST | jreher | Updated APD location via API. |
| 21. Jul 2020 14:45:01 CEST | jreher | Updated box and position via API. |
| 19. Dec 2019 16:48:01 CET | spankonin | Updated APD batch assignment via API. |
| 19. Dec 2019 15:19:02 CET | jreher | Updated box and position via API. |
| 20. Oct 2017 14:31:54 CEST | markus.moritz | Entered shipped after irradiation date. |
| 20. Oct 2017 09:51:22 CEST | markus.moritz | Entered irradiation information. |
| 29. Sep 2017 11:33:00 CEST | markus.moritz | Entered arrival for irradiation date. |
| 01. Aug 2016 17:29:33 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 23. Jun 2016 10:39:48 CEST | Tobias | Imported from Hamamatsu datasheet. |