RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1410015840 - Archived data from Tue, 11. August 2020 17:25:39 CEST


This is all the information about APD 1410015840. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1410015840
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E11
Break-through voltage: 427 V
Voltage for Gain 100 (T=+25°C): 399.1 V
Dark current: 6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 37
Position in Box: 4
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 391
Position in grid: 3
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 03. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 05. Dec 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 10. Dec 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 399.3057719 V     T = -25 °C: 362.4026077 V
Voltage for Gain 150: T = +20 °C: 407.2360377 V     T = -25 °C: 370.2022455 V
Voltage for Gain 200: T = +20 °C: 411.6246617 V     T = -25 °C: 374.5496233 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.380207304 V-1     T = -25 °C: 4.468014597 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.49284649 V-1     T = -25 °C: 8.579381046 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.46115279 V-1     T = -25 °C: 14.63317299 V-1
Break-through voltage: T = +20 °C: 426.7450192 V     T = -25 °C: 389.8153636 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:52:46 CET jreher Updated box and position via API.
03. Feb 2021 18:18:41 CET jreher Updated box and position via API.
11. Aug 2020 17:25:39 CEST jreher Updated APD characteristics via API.
28. Nov 2019 12:23:10 CET jreher Updated APD location via API.
25. Nov 2019 17:13:47 CET jreher Updated box and position via API.
13. Jun 2019 11:29:54 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:08 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:04 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 12:57:53 CET markus.moritz
29. Sep 2017 12:25:44 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:25 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:39:42 CEST Tobias Imported from Hamamatsu datasheet.